Take a free South Carolina RCRA practice test online: a full 35-question paper with every answer explained, no sign-up, scored by topic. The full 35-question bank and the timed simulator are $14.99 for 30 days.
EPA RCRA Hazardous Waste Generator (SC): a 35-question practice bank for the real EPA Environmental standard, 3 full papers of 35 questions each with no repeats, every question written to the regulation it comes from.
Every question in this bank cites a source -- primarily 40 CFR (69%) and S.C. Code Regs. (17%) of this exam's citations.
Correct answer: A. Very Small Quantity Generator (VSQG)
Correct. 40 CFR 262.13 defines a VSQG as generating 100 kg/month or less of hazardous waste and 1 kg/month or less of acute hazardous waste; South Carolina's R.61-79.262 incorporates this federal generator category structure.
Correct answer: B. Small Quantity Generator (SQG)
Correct. SQGs generate more than 100 kg but less than 1,000 kg of hazardous waste per calendar month, which fits 450 kg.
Correct answer: B. Is determined based on the amount of hazardous waste generated in a given calendar month and can change from month to month
Correct. Under R.61-79.262.A.13, a generator's category is based on the quantity of hazardous waste (and acute hazardous waste) generated each calendar month, so a facility's category can shift month to month with its waste generation.
Correct answer: A. 90 days
Correct. 40 CFR 262.17 sets the LQG on-site accumulation time limit at 90 days without a permit.
Correct answer: C. 270 days
Correct. 40 CFR 262.16 extends the SQG accumulation limit to 270 days when the waste must travel more than 200 miles to its designated facility.